| Sign In | Join Free | My benadorassociates.com | 
              
  | 
      
Brand Name : Biokey
Model Number : BIK-QL-H0014
Certification : CE
Place of Origin : Guangzhou China
MOQ : We can produce liquid and lyophilized kits
Price : USD
Payment Terms : L/C, T/T, Western Union
Supply Ability : 100,000 per day
Delivery Time : Depending on order quantity
Packaging Details : Carton package
Package : 96 tests/kit
expiration date : 12 months
Storage : -20±5℃
Applicable : Micgene 244/244 IVD(BIO-KEY)
LoD : 5 copies/μL
CV : ≤5%
Herpes simplex virus 6 (HSV-6) real-time PCR detection kit (lyophilized)
--96 tests/kit
 
 Intended use:
  
This kit, adopting Real-Time PCR-Fluorescence technology, is used for detection of herpes simplex virus 6 (HSV-6). It can be used for the laboratory diagnosis and monitoring of the herpes simplex virus 6 (HSV-6) infection. The test results are only for clinical reference, not for case confirmation or exclusion.
 
 Principle:
  
The specific primers and specific fluorescent probes are designed for the nucleic acid conserved region of herpes simplex virus 6 (HSV-6). The PCR reaction solution and real-time fluorescent quantitative PCR detection technology is applied on the fluorescence quantitative PCR instrument to realize the rapid detection of herpes simplex virus 6 (HSV-6) through the change of fluorescence signal. The detection system contains a human internal control (IC) gene, which is used to monitor whether the specimens and the process of nucleic acid extraction is qualified.
 
 Main components:
  
| No. | Components | BIK-QL-H0014 | 
|  			    |  			 			 PCR Enzyme Mix (Lyophilized)  |  			 			 96 tests/bottle  |  		
| 2 | HSV-6 Primer-Probe Mix | 100 μL/vial | 
| 3 | Enzyme Mix Buffer (5×) | 400 μL/vial | 
| 4 | Positive Control | 100 μL/tube | 
| 5 | Negative Control | 100 μL/tube | 
| 6 | RNase-free water | 1mL/tube | 
| 7 | Paraffin oil | 1.5mL/tube*2 | 
  Note: Do not mix the components from different batches for detection. The Positive Control of HSV-6 and internal control were constructed artificially, and they were not infectious.
  
 Product lyophilization package:
  
 
  
 Specimen requirements:
  
 1.Specimen type :
 Urethral swabs, cervical swabs or rectal swab.
  
 2.Specimen preservation:
 The specimen can be stored for 3 months at -20±5℃ and for a long time below -70℃.
  
  
Reaction mix preparation:
  
 Refer to the tables below to prepare the reaction mix:
| 1×volume required | |
| Resuspended master mix | 14 μL | 
|  			 HSV-6 Primer & probe  |  			1 μL | 
| Total volume | 15 μL | 
※Multiply the numbers according to the number of tests.
  
  
Operation details please check from IFU!
| 
                                             | 
                
                        Herpes Simplex Virus 6 HSV-6 96tests/Kit Real Time PCR Detection Kit Lyophilized Images |